-6% Off

Drager Oxylog 3000 Ventilator

(2 customer reviews)

$3,280

Better ventilation performance

The Drager Oxylog® 3000 offers a sophisticated performance in emergency and transport ventilation – so good it can be used to ventilate critical-care patients in transfer situations. Your patients will appreciate not having to fight what they often feel is unpleasant: controlled ventilation. Here, the SIMV mode and other spontaneous modes can actively support a patient’s breathing. A new option is the combination of pressure-controlled and spontaneous ventilation during the entire breathing cycle (BIPAP*). Similar to a paramedic feeling the changed pressure in the bag when a patient starts breathing again, the Oxylog 3000® recognizes insufficient spontaneous breathing and can automatically support the patient’s breathing (ASB*). If intubation is to be avoided, non-invasive mask ventilation (NIV) with leakage compensation is possible. In the event of an apnea in the CPAP/PS mode, the Oxylog 3000 automatically initiates volume-controlled mandatory ventilation after a user defined apnea time. But the Oxylog 3000 is not just distinguished by a wide range of ventilation modes. A tidal volume that starts at just 50 ml allows the Oxylog 3000 to be used for small children, while the patented blender permits a low oxygen concentration of as little as 40%. The oxygen concentration is continuously adjustable from 40 to 100%. When it comes to transport ventilation performance, it’s better to have an Oxylog 3000.

Better for transport

Despite the Oxylog 3000’s outstanding ventilation qualities, this device is as tough as they come. It is designed to withstand
being dropped from heights of up to 75 cm (29.5 inches), is suitable for use in helicopters, is spray-proof and functions well in extreme temperatures. Its entirely new design is light, compact and easy to carry because the Oxylog 3000 is driven
by a high-pressure gas supply, no internal blower is necessary. Another innovation is the Oxylog’s smart battery. It will last
for up to four hours, has a built-in chip to provide remaining battery capacity information and is easy to exchange. The
Oxylog 3000 also offers options such as 100% O2 flush or O2 inhalation. When the conditions get tough, it’s better to have
an Oxylog 3000.

Better and safe operation

The Oxylog 3000 is designed to make life easier for the operator. Dräger’s well known rotary knob brings a convenient level of
simplicity to the vital business of setting parameters. One hand and three simple steps, “select – adjust – confirm”, are all
you need. In addition to the rotary knob, a common feature of many Dräger devices, the Oxylog 3000 also has four direct
control knobs that enable parameters to be set quickly – often essential in emergency situations.

As well as setting ventilation parameters, reading them quickly and accurately is just as important. The Oxylog 3000’s large, high-contrast display shows readings, settings and flow or pressure curves at a glance. Alarm signals and status displays provide additional help in spotting problems and dealing with them quickly. In critical emergency care situations you and your patient will be better off with an Oxylog 3000.

Technical data
*Oxylog® 3000 is a time-cycled, volume-constant and pressure-controlled emergency and transport ventilator for patients with a tidal volume starting at 50 mL.

  • Dimensions: (W x H x D) 285 x 184 x 175 mm / 11.10 x 7.24 x 6.89 inch (excluding handle)
  • Weight: 5,4 kg / 11.9 lbs (including internal battery)
  • Gas supply: From a central gas supply system or from a medical gas cylinder
  • Supply Gas: Medical Oxygen or Medical Air
  • Supply Pressure: 39 – 87 PSI / 270 – 600 kPa at 100 L/min
  • Gas consumption for internal control 0.1 to 0.5 L/min

Operating data

  • Ventilation Modes: IPPV/IPPVassist*, SIMV, SIMV/ASB*, BIPAP*, BIPAP*/ASB*, CPAP, CPAP/ASB*
  • Special Modes: NIV (Non-invasive (mask)-ventilation with leakage compensation) & Apnea Ventilation (For switching over automatically to volume-controlled mandatory ventilation, if breathing stops) CPR-mode Pressure-limited, non-constant-volume ventilation during inspiration time when Pmax is reached Ventilation frequency 2 – 60 BPM (SIMV and BIPAP*); 5 – 10 BPM (IPPV*); 12 – 60 BPM (Apnea ventilation)
  • Tidal Volume VT:  50 to 2000 mL, BTPS**
  • Ventilation Time Ratio I:E (IPPV*):  1:4 to 3:1
  • Inspiration Time Tinsp. (SIMV, BIPAP*):  0.2 to 10 sec
  • Inspiratory Pressure Pinsp: PEEP + 3 to 55 mbar / cmH2O
  • O2 Concentration: 40 to 100%, infinitely adjustable
  • PEEP: 0 to 20 mbar / cmH2O
  • Trigger Sensitivity (flow trigger):  3 to 15 L/min
  • Pressure Support Δ ASB*:  0 to 35 mbar / cmH2O (relative to PEEP), rise time adjustable in 3 steps
  • Max. Inspiratory Flow : 100 L/min (supply pressure > 350 kPa / 51 PSI), 80 L/min (supply pressure < 350 kPa / 51 PSI)
  • Measured Value Display:  MV, f, VTe, PEEP, Pmean, Ppeak, Pplat, MVspn, fspn, O2***
  • Display Technology: Electro-luminescence, Pixels: 240 * 128, Visible area: 108 * 56 mm / 4.25 x 2.20 inch
  • Curve Display: Pressure curve, flow curve

Power supply

  • Input Voltage:  19 V DC
  • AC/DC Power Pack: 100 to 240 V AC / 19 V DC
  • DC/DC Converter:  10 to 32 V DC / 19 V DC
  • Battery Type: Lithium ion
  • Operating time (fully charged, “typical” ventilation):  Approx. 4 hours (Lithium ion)
  • Battery Charging Time:  Approx 5 hours (Lithium ion)

Monitoring

  • Supply Pressure Low:  Supply pressure < 270 kPa / 39 PSI
  • Airway Pressure (Paw high): Adjustable from 20 to 60 mbar / cmH2O
  • Airway Pressure (Paw low):  When pressure difference between Insp. and Exp. < 5 mbar / cmH2O or when the set pressure level is not reached
  • Apnea Alarm Time TApnea:  When respiratory activity is no longer detected, adjustable from 15 to 60s
  • Leakage (not in NIV):  VTexp. is approx. 40% lower than VTinsp.
  • High Frequency: Patient breathes at a high spontaneous rate

Operating conditions

  • Temperature: – 20 to 50 °C / 14 to 122 °F
  • Atmospheric Pressure:  570 to 1200 hPa / 17 to 35 in. Hg
  • Rel. Humidity: 5 to 95%
  • Electromagnetic Compatibility EMC:  In accordance with IEC/EN 60601-1-2:2001 and ISO 10651-3
  • Airworthiness: In accordance with RTCA DO-160D, sections 7, 8 & 21
  • Mechanical strength: In accordance with MIL STD 810F, method 514.5
  • Classification according to MDD 93/42/EEC: Class IIb
  • UMDNS-Code:  18-098
Compare

2 reviews for Drager Oxylog 3000 Ventilator

  1. madems

    Drager Oxylog 3000 Ventilator

    madems
  2. madems

    Ventilator for Virus Covid-19

    madems
Add a review

Your email address will not be published. Required fields are marked *


Warning: Undefined array key "cookies" in /home1/mademedicalsuppl/public_html/wp-content/themes/medilazar/inc/class-main.php on line 361